This facility is provided to enable any interested parties to search for Registered Medical Device, Registered CAB, Licensed Establishments under Section 5, 10, 15 of Medical Device Act 2012 (Act 737) respectively and Notified Medical Device under Medical Device (Exemption) Order 2016. Any party who wishes to know whether an establishment who is dealing with medical device has been licensed under Act 737 may search the establishment by inserting the establishment name or license number in the searching field below.


DEVICE DETAILS

NAME OF DEVICEPULSE OXIMETER (PO4)
ESTABLISHMENT NAMEMURSMEDIC MALAYSIA SDN. BHD.
ROLE OF ESTABLISHMENTAUTHORIZED REPRESENTATIVE
REGISTRATION NOGB10871624-184762
BRAND NAMELEPU MEDICAL
DEVICE GROUPING TYPESINGLE
DEVICE DESCRIPTIONThe pulse oxygen saturation, the percentage of HbO2 in the total Hb in the blood, namely the so-called O2 concentration in the blood, is an important bio-parameter for the respiration. The intergradations of oxygen molecule in the blood and hemoglobin in erythrocyte are reversible. Hemoglobins integrated with oxygen are called HbO2, and those released O2 are called HbR. Oxyhemoglobin and deoxyhemoglobin (HHb) absorb red Marginal and infrared of specific wavelength, thus the Marginal of the two wavelengths emitted from SpO2 sensor is absorbed when it passes through the finger, and approximate pulse oxygen saturation is calculated by measuring absorption of the Marginal.The device is a lightweight, portable health wrist oximeter for use in the home or in healthcare facilities. SpO2 measurement technology is based on developed photoelectron method, the circuit design and calculation software was developed by Shenzhen Viatom Technology Co., Ltd. The SpO2 sensor receives the optical signal from the red light and infra-red light through the finger. Insert the finger into the oximeter, there are two emitting tube (red light diodes and infrared diodes) located on the inner upside of the sensor and they can emit red light and infrared; There is the receiving end located on the inner downside of the sensor, and it can transmit the red light and infrared into the pulse signal through finger. The MCU receives the pulse signal, gets the frequency signal by counting, processes its digital signal, and finally gets the measured SpO2 value. The PR is averagely calculated by above peak intervals of PR waveform. The device is powered by internal battery. The device is not for life-supporting or lifesustaining, not for implant. The device or sensor is not sterile and the sensor does not need sterilization and the sensor is reusable but does not need re-sterilization since it is not sterile. The device is for prescription. The device does not contain drug or biological products. The device consist of main unit, SpO2 sensor, wristband and charging cable. The main unit is mainly composed of MCU (built-in Bluetooth module), Power circuit, SpO2 measurement circuit, Display control circuit, etc. that is an integrated product with modular design
DEVICE INTENDED PURPOSEThis product is intended to be used for measuring, displaying and storing of pulse oxygen saturation (SpO2), pulse rate of users in home or healthcare facilities environment.
VALIDITY DATE OF REGISTRATION13/09/2024 - 12/09/2029

LIST OF DEVICE

NONAME OF DEVICEDEVICE IDENTIFIER
1PULSE OXIMETER (PO4)PO4