This facility is provided to enable any interested parties to search for Registered Medical Device, Registered CAB, Licensed Establishments under Section 5, 10, 15 of Medical Device Act 2012 (Act 737) respectively and Notified Medical Device under Medical Device (Exemption) Order 2016. Any party who wishes to know whether an establishment who is dealing with medical device has been licensed under Act 737 may search the establishment by inserting the establishment name or license number in the searching field below.


DEVICE DETAILS

NAME OF DEVICEFINGERTIP PULSE OXIMETER
ESTABLISHMENT NAMECAREFORCE MEDICARE SUPPLIES SDN BHD
REGISTRATION NOGC9770721-65290
BRAND NAMEAURELIUS CARE
DEVICE GROUPING TYPEFAMILY
DEVICE DESCRIPTIONHaemoglobin Saturation is the percentage between the capacity of Oxyhemoglobin (HbO2) that compounded with oxygen and that of all combinativable haemoglobin (Hb) obin (HbO2) in blood. In other words, it is the saturation of Oxyhemoglobin in blood. It is a very important physiological parameter for Respiratory and Circulation Systems. Many respiratory diseases could reduce haemoglobin saturation in human blood. Moreover, factors such as Automatic Organic Regulation Malfunction caused by anaesthesia, trauma resulted from major operation and some medical examination can also cause problems in oxygen supply, which might reduce human haemoglobin saturation. As a result, such symptoms as megrim, vomiting and asthenia might appear to patients. Hence, it is very important to know hemoglobin saturation of patient timely in clinical medical aspects. The fingertip oximeter features in small volume, low power consumption, convenient operation and portability. It is only necessary for patient to put one finger into fingertip photoelectric sensor for diagnosis, and the display screen will directly show measured value of hemoglobin saturation. It has been proved in clinical experiments that it possesses rather high precision and repeatability.
DEVICE INTENDED PURPOSEThis Fingertip Oximeter is intended for measuring the pulse rate and functional oxygen saturation (SpO2) through a patient’s finger. It is applicable for spot-checking SpO2 and pulse rate of adult and pediatric patients in homes and medical clinics. Models with external sensor options and over-limit Indication may be used for longer periods of time dependent on the suitability of the sensor selected.
VALIDITY DATE OF REGISTRATION28/06/2021 - 27/06/2026

LIST OF DEVICE

NONAME OF DEVICEIDENTIFIER
1Fingertip Pulse OximeterAPO-20
2Fingertip Pulse OximeterAPO-20A
3Fingertip Pulse OximeterAPO-20C
4Fingertip Pulse OximeterAPO-30
5Fingertip Pulse OximeterAPO-30A
6Fingertip Pulse OximeterAPO-30C
7Fingertip Pulse OximeterAPO-KD1
8Fingertip Pulse OximeterAPO-KD2
9Fingertip Pulse OximeterAPO-KD3
10Fingertip Pulse OximeterAPO-KD8